3-Stage Heat Pump
Manual Changeover
Battery or Hardwired
SC 2210
Non-Programmable Electronic Thermostat
Installation, Operation & Application Guide
For more information on our complete range of American-made
products – plus wiring diagrams, troubleshooting tips and more,
visit us at www.icmcontrols.com
Configurable
Three Stage Heat Pump Systems
Backlit Display
Field Calibration Feature
Filter Check
Relay Outputs
(minimum voltage drop in thermostat)
Ideally Suited for:
Residential (New Construction/Replacement)
Light Commercial
Przeglądanie stron 0
1 2 3 4 5 6 ... 27 28

Podsumowanie treści

Strona 1 - Battery or Hardwired

3-Stage Heat Pump Manual ChangeoverBattery or HardwiredSC 2210Non-Programmable Electronic ThermostatInstallation, Operation & Application GuideFor

Strona 2 - Table of Contents

8SC 2210 Electronic ThermostatSimpleComfort® 2210 Electronic Thermostat Conversion to:Heil-Quaker 867.814 Series and PH50 Series Heat Pump SystemsRYOG

Strona 3 - Parts Diagram

9SC 2210 Electronic Thermostat24 VAC, ReturnCompressor ContactorReversing Valve (Cooling Mode)Fan Contactor CircuitEmergency Heating Circuit2nd Stage

Strona 4 - Important Safety Information

10SC 2210 Electronic Thermostat24 VAC, ReturnCompressor ContactorReversing Valve (Heating Mode)Fan Contactor Circuit2nd Stage Heating CircuitSystem Mo

Strona 5 - To Install Thermostat

11SC 2210 Electronic ThermostatRYOGX2W-UBTSimpleComfort® 2210 Electronic Thermostat Conversion to:Goodman, Janitrol, Trane/American Standard Heat Pump

Strona 6

12SC 2210 Electronic ThermostatSimpleComfort® 2210 Electronic Thermostat Conversion to:York -E1CS, -E1FB, -E1FH Heat Pump SystemsRYOGWXB24 VAC, Return

Strona 7 - Wiring Diagram Conversions

13SC 2210 Electronic ThermostatRYOGEW1LCTSimpleComfort® 2210 Electronic Thermostat Conversion to:Lennox CB19 Heat Pump Systems24 VAC, ReturnCompressor

Strona 8

14SC 2210 Electronic ThermostatV-VRMRFEYXSimpleComfort® 2210 Electronic Thermostat Conversion to:Lennox HP19 and HP20 Heat Pump Systems24 VAC, ReturnC

Strona 9

15SC 2210 Electronic ThermostatSimpleComfort® 2210 Electronic Thermostat Conversion to:Lennox HP21 With CB21 PCB Heat Pump SystemsR-VRY1OFEW1LXY224 VA

Strona 10 - SimpleComfort

16SC 2210 Electronic ThermostatR-VRMRFEYLXY2Lennox HP22 with CB19 PCBLow Voltage Terminal BoardSimpleComfort® 2210 Electronic Thermostat Conversion to

Strona 11

17SC 2210 Electronic ThermostatSimpleComfort® 2210 Electronic Thermostat Conversion to:FHP 1 Heat Pump SystemsRYOGEWC24 VAC, ReturnCompressor Contacto

Strona 12

Table of ContentsParts Diagram ...

Strona 13

18SC 2210 Electronic ThermostatRYOGCY2FHP 2 Stage HPLow Voltage Terminal BoardSimpleComfort® 2210 Electronic Thermostat Conversion to:FHP 2 Heat Pump

Strona 14

19The configuration mode is used to set the SC2210 to match your heating/cooling system. The SC2210 functions with up to 3-stage heat pump systems.To c

Strona 15 - (capped)

20FILTERDIFFROOMSETREMOTE9. Maximum compressor cycles allowed per hour (-, 2-6) - = as many as needed, 2-6 = maximum cycles/hour Press the or

Strona 16

2110. Filter Check time (300-800, – – –) Set Fan Run Time (in hours) when Check Filter is displayed or set to – – – to disable. Press the or b

Strona 17

22There are three LED indicators located on the front of the thermostat. They are designed to inform you about the following:LED Color FunctionAUX Gr

Strona 18

23Cool Test1. Slide Mode switch to Cool mode. 2. Adjust set temperature so it is 5 degrees below room temperature. 3. Air conditioning should come

Strona 19

24Fan Test1. Slide Fan switch to On position. 2. Indoor fan turns on.Auto OnAuto On3. Slide Fan switch to Auto position. 4. Indoor fan

Strona 20

25Symptom RemedyNo display For Hardwired InstallationCheck for 24 VAC at thermostat; display is blank when 24 VAC is not presentFor Battery Installati

Strona 21 - Conguration Mode

ONE-YEAR LIMITED WARRANTYThe Seller warrants its products against defects in material or workmanship for a period of one (1) year from the date of man

Strona 22

1Parts Diagram

Strona 23 - SC2210 Output Chart

2Package Contents/Tools RequiredSpecicationsElectrical rating: • 24 VAC (18-30 VAC) • DC Power: 3.0 VDC (2 “AA” batteries included) • 1 amp maxim

Strona 24 - LED Indicators

3To Remove Existing ThermostatELECTRICAL SHOCK HAZARD – Turn off power at the main service panel by removing the fuse or switching the appropriate cir

Strona 25 - Emergency Heat Test

4To Install Thermostat (continued)2. To remove cover, insert and twist a coin or screwdriver in the slots on the sides of the thermostat.3. Put ther

Strona 26 - Mode of Operation

5SimpleComfort® 2210 Electronic Thermostat Conversion to:Carrier Split Stream Condensers and Heat Pump Systems24 VAC, ReturnCompressor ContactorRevers

Strona 27 - Troubleshooting

6SC 2210 Electronic ThermostatSimpleComfort® 2210 Electronic Thermostat Conversion to:Coleman 3000 Series Heat Pump Systems24 VAC, ReturnCompressor Co

Strona 28 - ONE-YEAR LIMITED WARRANTY

7SC 2210 Electronic ThermostatRYOGW1W2XCSimpleComfort® 2210 Electronic Thermostat Conversion to:ComfortMaker CYC Series Heat Pump Systems24 VAC, Retur

Komentarze do niniejszej Instrukcji

Brak uwag